FR-A10010

UNMONITORED STANDARD MAGNET

  • Operating voltage 12~24Vdc (Selectable)
  • Aluminium housing
  • Unmonitored
  • Safety bolts fitted
  • Fire tested: BS EN1634:1
  • Holding force up to 1200lbs (544Kg)
  • Electro-less nickel plated armature

Description

  • Voltage tolerance: ±10%.
  • Current draw: 420mA at 12Vdc, 210mA at 24Vdc (at temperature 20°C).
  • Operating temperature: -10~55°C (14 to 131°F).
  • Lock’s surface temperature: Current temperature ±20% (when power is on).
  • Magnetic bond sensor monitor output remotely monitors the door lock or unlock status. (N.C. Output-Door opened; N.O. Output-door closed) (SPDT rated 0.25A at 12Vdc).
  • Aluminium housing, nickel plated armature.
  • Humidity: 0~95% non-condensing.
  • Weight: 4.7kg (approx).
CP21-N Wiring Diagram

Additional information

Weight 4.7 kg
Dimensions 268 × 67 × 40 mm